Light Weight Snl7 3p Series ( MCB ) Miniature Circuit Breaker 63A 10ka

Brand Name : SONTUOEC ,WZSTEC

Model Number : SNL7

Certification : CE

Place of Origin : China

MOQ : 10000PCS

Price : Negotiable

Supply Ability : 10000PCS/DAY

Packaging Details : 240PCS/CTN

Delivery Time : 20DAYS

case material : PA66

Ue : 230/400V

In : 1,2,4,6,10,16,20,25,32,40,50,63A

Breaking Capacity : 3KA,4.5KA,6KA,10KA

Pole : 1P,2P,3P,4P

performance : moisture resistant

Contact Now

Hot Sale Snl7 3p Series (MCB) Miniature Circuit Breaker 63A 10ka​

GENERAL

SNL7 series high breaking capacity mini circuit breaker is used in AC50/60Hz, rated voltage of 230V

3, 4 poles 400V, rated current to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC60898 standard.

1.Application:For protecting cables and equipments against overload and short circuit.

2.General rules for choosing MCB.

a.Technical data of the network at the point considered

The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.

b.There are 3 curvve characteristics for magnetic operation:

B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.

C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.

D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)

Advantages:


High breaking capacity , all rated current can reach 6KA;


Many kinds of accessories can be chosen, in modularize and flexibility combine that make the customer install conveniently;


The cover and function parts both are made of inflaming retarding, bear high temperature and bear impact plastic;


The breaker is applicable to lighting distribution system in industrial enterprise, commercially district, high-rise building and dwelling house.

Specifications

Model

SNL7
Pole 1p,2p,3p,4p
Rated Current(In) 1,2,4,6,10,16,20,25,32,40,50,63A
Rated Voltage(Un) 230/400V
Rated Frequency 50/60HZ
Tripping curve B,C,D
Magnetic releases B curve: between 3and 5 In
C curve: between 5and 10In
D curve: between 10 and 14In
Electro-mechanical endurance over 6000 cycles

Standard IEC/EN 60898-1
Electrical
features
Rated current In A 1,2,4,6,10,16,20,25,32,40,50,63
Poles P 1,2,3,4
Rated voltage Ue V 230/400
Insulation voltage Ui V 500
Rated frequency Hz 50/60
Rated breaking capacity A 4500,6000
Rated impulse withstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1 min Kv 2
Pollution degree 2
Thermo-magnetic release characteristic B,C,D
Mechanical
features
Electrical life t 4000
Mechanical life t 10000
Protection degree IP20
Reference temperature for setting
of thermal element
30
Ambient temperature
(with daily average ≤35℃)
-5~+40(Special application please refer to
temperature compensation correction)
Storage temperature -25~+70
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable mm2 25
AWG 18-3
Therminal size top/bottom for busbar mm2 25
AWG 18-3
Tightening torque N*m 2
In-lbs 18
Mounting on DDIN rail EN 60715(35mm)by means of fast clip device
Connection From top and bottom

Product Usage:

General rules for choosing MCB,For protecting cables and equipments against overload and short circuit.

a. Technical date of network at the point considered:

The earthing systems,short-circuit current at the circuit breaker installation point ,which must always be less than the breaking capacity of this device,network normal voltage.

b. There are 3 curve characteristics for magnetic operation:

B curve (3-5 ln) protection and control of the circuits against length cables in TN and IT systems.

C curve (5-10 ln) protection and control of the circuits against overloads and short-circuits; protecton for resistive and inductive loads with low inrush current.

D curve (10-20 ln) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps)

Our services have competitively price,we can provide after sale service,our product quality are very good,it has a long life

Product Tags:

miniature circuit breaker

      

automotive circuit breaker

      
Best Light Weight Snl7 3p Series ( MCB ) Miniature Circuit Breaker 63A 10ka wholesale

Light Weight Snl7 3p Series ( MCB ) Miniature Circuit Breaker 63A 10ka Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WENZHOU SANTUO ELECTRICAL CO.,LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)